S-207 |
|
 |
Home
|
S-207
Standard/Nonasbestos Gasket material
F339999E99M9 |
|
|
| S-207 is a cellulose fiber gasket material with controlled-swell styrene butadiene rubber binder. It is a suitable replacement for asbestos fiber gasket materials, saturated papers, and is used in many oil and coolant applications in the aftermarket. It is intended for use in applications with short duration maximum temperatures up to 180oC (350oF).
|
|
|
 |
|
Density, g/cc(lb/cu.ft) |
0.88 (55) (min.) |
ASTM F 1315 |
|
Compressibility, % (at 6.9MPa) |
10 - 30 |
ASTM F 36 |
|
Recovery, % |
30 (min.) |
ASTM F 36 |
|
Tensile Strength, AMD, MPa(psi) |
9.66 (1400) (min.) |
ASTM F 152 |
|
Fluid Resistance, IRM903 Oil |
|
ASTM F 146 |
 | Change in Thickness, % |
|
35 (max.) |
|
 | Change in Weight, % |
|
70 (max.) |
|
|
Fluid Resistance, Fuel B |
|
ASTM F 146 |
 | Change in Thickness, % |
|
50 (max.) |
|
 | Change in Weight, % |
|
65 (max.) |
|
|
Fluid Resistance, Distilled Water |
|
ASTM F 146 |
 | Change in Thickness, % |
|
50 (max.) |
|
 | Change in Weight, % |
|
65 (max.) |
|
|
Binder Type |
Styrene Butadiene |
|
|
 |
|
| Specification values determined by the test methods required for ASTM F-104, Type 3 materials. |
|
|
|
EnCore, Hydro-Fused, Pro-Formance, Select-a-Seal, Syntheseal, Thermo-Tork, and Voltoid are registered trademarks of Interface Solutions, Inc. MicroPore is a trademark of Interface Solutions, Inc.
WARNING: The description and performance data provided herein constitute a material specification for quality control purposes, but do not imply suitability for use in a specific application. Your specific application should not be undertaken without independent study and evaluation for suitability. Failure to select proper sealing products may result in either property damage or personal injury. For specific application recommendations, contact Interface Solutions. INTERFACE SOLUTIONS EXPRESSLY DISCLAIMS ALL WARRANTIES EITHER EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT WILL ISI BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL OR PUNITIVE DAMAGES, HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THE INFORMATION CONTAINED IN ITS SPECIFICATION DATA SHEETS, ITS PRODUCTS OR THEIR FUTURE USE BY YOU OR ANY THIRD PARTIES, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
|
| |