NI-4002 |
|
 |
Home
|
NI-4002
Standard/Nonasbestos Gasket Material
F339997E92M9 |
|
|
| NI-4002 is a non-asbestos facing material that, when combined on perforated metal core, is intended for elevated temperature applications such as exhaust systems. It has an inorganic filler system encapsulated by nitrile butadiene rubber binder, giving it low ignition loss and good torque retention properties. |
|
|
 |
|
Density, g/cc(lb/cu.ft) |
0.88 (55) (min.) |
ASTM F 1315 |
|
Compressibility, % (at 6.9MPa) |
15 - 30 |
ASTM F 36 |
|
Recovery, % |
25 (min.) |
ASTM F 36 |
|
Tensile Strength, AMD, MPa(psi) |
2.07 (300) (min.) |
ASTM F 152 |
|
Fluid Resistance, IRM903 Oil |
|
ASTM F 146 |
 | Change in Thickness, % |
|
10 (max.) |
|
 | Change in Weight, % |
|
70 (max.) |
|
|
Fluid Resistance, Fuel B |
|
ASTM F 146 |
 | Change in Thickness, % |
|
10 (max.) |
|
 | Change in Weight, % |
|
55 (max.) |
|
|
Fluid Resistance, Distilled Water |
|
ASTM F 146 |
 | Change in Thickness, % |
|
15 (max.) |
|
 | Change in Weight, % |
|
80 (max.) |
|
|
Binder Type |
Nitrile Butadiene |
|
|
 |
|
| Specification values determined by the test methods required for ASTM F-104, Type 3 materials. |
|
|
|
EnCore, Hydro-Fused, Pro-Formance, Select-a-Seal, Syntheseal, Thermo-Tork, and Voltoid are registered trademarks of Interface Solutions, Inc. MicroPore is a trademark of Interface Solutions, Inc.
WARNING: The description and performance data provided herein constitute a material specification for quality control purposes, but do not imply suitability for use in a specific application. Your specific application should not be undertaken without independent study and evaluation for suitability. Failure to select proper sealing products may result in either property damage or personal injury. For specific application recommendations, contact Interface Solutions. INTERFACE SOLUTIONS EXPRESSLY DISCLAIMS ALL WARRANTIES EITHER EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE. IN NO EVENT WILL ISI BE LIABLE FOR ANY INDIRECT, SPECIAL, INCIDENTAL, CONSEQUENTIAL OR PUNITIVE DAMAGES, HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THE INFORMATION CONTAINED IN ITS SPECIFICATION DATA SHEETS, ITS PRODUCTS OR THEIR FUTURE USE BY YOU OR ANY THIRD PARTIES, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
|
|
| |
Interface Sealing Solutions
22260 Haggerty Road , Suite 200 Northville, MI 48167
|
|
Tel: (248) 596-2800 Fax: (248) 596-2880
|
|
|
Previous Revision Date: 09-20-2005 Latest Revision Date: 12-14-2005
|
|
 |
 |
|
|
|